Contact  

Flamro Brandschutz-Systeme GmbH

Am Sportplatz 2
56291 Leiningen
Tel: +49 6746 9410-0
Fax: +49 6746 9410-10
Email:info@flamro.de

BC Seal 90/Combi

BC Seal 90/Combi

Permitted Configuration • Electric cables and lines of all types (except waveguide cable) • Tightly tied-up cable bundle up to Ø 100 mm (single cable no greater than 20 mm) • Fibre optic cable • Cable supporting structures made from steel, aluminium, plastic • Non-combustible pipe conduits made from steel, stainless steel and cast iron up to Ø 168.3 mm; copper up to Ø 88.9 mm • Combustible pipe conduits made from plastic (standard commercial B1 and B2 qualities) up to DN 160 • Individual lines made from steel or plastic pipes for Control purposes up to max. 15 mm • Pipe insulation made from combustible synthetic rubber and PVC-sheathed multicore tubes
more
BC Seal 90/UNO

BC Seal 90/UNO

Permitted Configuration • Electric cable or required thickness and materials • Fibre optic cable (but no waveguide cable) • Tightly tied-up cable bundle up to Ø 100 mm (single cable no greater than 20 mm) • Individual control cables made from steel or plastic pipes up to 15 mm • Cable ducts, trays, ladders made from steel, aluminium or plastic profiles
more
BC Seal 120

BC Seal 120

Permitted Configuration • Electric cable of required thickness and materials • Fibre optic cable (excluding waveguide cable) • Tightly tied-up cable bundle up to Ø 100 mm (single cable no greater than 18 mm) • Individual control cables made from steel or plastic pipes up to 15 mm • Cable ducts, trays, ladders made from steel, aluminium or plastic profiles
more
BC Fire Protection® Seal S 90 FM I Combi

BC Fire Protection® Seal S 90 FM I Combi

Permitted Configuration • Electric cables and lines of all types • Fibre optic cable • Waveguide cable HELIFLEX • Cable supporting structures made from steel, aluminium, plastic • Non-combustible pipe conduits made from steel, stainless steel and cast iron up to 168.3 mm; Copper up to 88.9 mm • Combustible pipe conduits made from types of plastic (standard B1 and B2 qualities) up to 110 mm • Individual lines made from steel or plastic pipes for control purposes up to max. 15 mm
more
BC Ferrocoat 30-90

BC Ferrocoat 30-90

Permitted Configuration • Steel beams • Steel girders • Truss members
more
Woodcoat Transparent New

Woodcoat Transparent New

For timbers in interiors, which are not subject to severe wear and tear due to mechanical loads
more
BC Paint

BC Paint

For timbers in interiors, which are not subject to severe wear and tear due to mechanical loads
more
Cable Coating System 1

Cable Coating System 1

• Electric cable of required thickness and materials • Cable trays made from steel or aluminium profiles
more
Cable Coating System 2

Cable Coating System 2

• Electric cable of required thickness and materials • Cable trays made from steel or aluminium profiles
more
Gap Filling Rope RP 55

Gap Filling Rope RP 55

Permitted Configuration • Walls (masonry, concrete or aerated concrete) ≥ 150 mm • Ceilings (concrete or aerated concrete) ≥ 150 mm • Gap width max. 55 mm
more
BSB-K combi seal EN<br>EI 90 / EI 120

BSB-K combi seal EN
EI 90 / EI 120

Flexible combi seal for the sealing of cables and pipes consisting of the FLAMRO BSB-K fire protection bricks. Approved for the following penetrants: Single cables ≤ Ø 21 mm Cable bundles ≤ Ø 100 mm Cable trays Sheathed cables ≤ Ø 80 mm Core cables ≤ Ø 24 mm Electrical installation pipes ≤ Ø 25 mm Plastic pipes ≤ Ø 75 mm Metal pipes ≤ Ø 54 mm
more
BS-MK combi seal<br>max. EI 120

BS-MK combi seal
max. EI 120

Panel seal (soft seal) for wall penetrations to protect both single and bundled cables (including optical fiber cables) and their supporting structures (cable trays and ladders) made of steel as well as pipes listed in the ETA-15/0237. Non-combustible pipes (e.g. steel) ≤ 108 mm Copper pipes ≤ 88,9 mm Combustible pipes made of PVC ≤ 110 mm Single cables up to Ø 80 mm Cable bundles up to Ø 100 mm Conduits ≤ 25 mm Rubber insulated pipes AF/Armaflex Waveguide cables ≤ 50,4 mm Single core lines ≤ 24 mm
more
KMO combi mortar seal<br>S 90

KMO combi mortar seal
S 90

Pumpfähiger Brandschutzmörtel für Wand- und Deckendurchführungen zur Abschottung von einzelnen oder gebündelten Elektroleitungen und -kabeln (auch Lichtwellenleiter) ohne Begrenzung des Gesamtleiterquerschnitts des einzelnen Kabels und deren Tragekonstruktionen (Kabelrinnen, -pritschen, -leiter) aus Stahl, Aluminium oder Kunststoff, sowie Durchführung von brennbaren und nichtbrennbaren Rohren, Elektro-Installationsrohren und Heliflex-Hohlleiterkabeln.
more
DSB-W

DSB-W

• Subject to third-party inspection in accordance with the certification (building material approval) • Permitted only for single lines in accordance with LAR provisions • Not suitable for outdoor use! Do not expose to moisture (as salts may be washed out so that proper functioning is no longer ensured)!
more
M3 Mortar

M3 Mortar

Brandschutzmörtel FLAMRO M3 ist ein werkseitig gemischter Trockenmörtel, hydraulisch abbindend. Nichtbrennbarer Baustoff- DIN 4102-1, A1. Mörtelgruppe CS IV nach EN 998-1 (ehemalige deutsche Norm – DIN 1053-1 MG lll). Die Produktion unterliegt der Güteüberwachung.
more
multi-combi seal EN<br>max. EI 120

multi-combi seal EN
max. EI 120

Panel seal (soft seal) for wall and floor/ceiling penetrations to protect both single and bundled cables (including optical fiber cables) and their supporting structures (cable trays and ladders) made of steel as well as pipes listed in the ETA-13/0756. Non-combustible pipes made from steel, stainless steel, cast steel ≤ 168.3 mm CU pipes ≤ 88.9 mm Combustible pipes made from plastic ≤ 160 mm Sheathed cables up to Ø 80 mm Cable bundle up to Ø 100 mm Installation pipes ≤ 25 mm Synthetic rubber insulated pipes Armaflex Protect Ducts up to 25 mm, rigid | flexible | occupied | unoccupied | combustible | non-combustible | also as bundle
more
multi-combi seal<br>S 90

multi-combi seal
S 90

Panel seal (soft seal) for wall and floor/ceiling penetrations, designed for the protection of both single and bunched electrical lines and cables (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics, and of pipes (in accordance with Approval No. Z-19.15-1279 (Sections 1.2.7 ff.).
more
BK pad seal<br>S 90

BK pad seal
S 90

Pillow seal for wall and floor/ceiling penetrations, designed for the protection of single and bunched electrical lines and cables (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastic. Also permitted for the protection of penetrating single steel and plastic pipes < 15 mm.
more
BS-1 panel seal<br>EI 60 / EI 120

BS-1 panel seal
EI 60 / EI 120

Panel seal (soft seal) for wall and floor/ceiling penetrations, designed for the protection of both single and bunched electrical lines and cables (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics.
more
BS panel seal<br>S 90

BS panel seal
S 90

Panel seal (soft seal) for wall and floor/ceiling penetrations, designed for the protection of both single and bunched electrical lines and cables (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics.
more
BSB fire protection bricks<br>S 30 / S 60

BSB fire protection bricks
S 30 / S 60

Elastic firestop bricks for wall penetrations, designed for the protection of single and bunched electrical lines and cables of all types (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics. Also permitted for the protection of penetrating single steel and plastic pipes < 15 mm.
more
BSB fire protection bricks<br>S 90 / S 120

BSB fire protection bricks
S 90 / S 120

Z-19.15-1762 Wall Penetration Seal Z-19.15-1763 Floor / Ceiling Penetration Seal Elastic firestop bricks for wall and floor/ceiling penetrations, designed for the protection of single and bunched electrical lines and cables of all types (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics. Also permitted for the protection of penetrating single steel and plastic pipes < 15 mm.  
more
BSS foam seal<br>S 30

BSS foam seal
S 30

Elastic firestop foam for wall and floor/ceiling penetrations, designed for the protection of both single and bunched electrical lines and cables of all types (including optical fibre cables), as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics.Also permitted for the protection of penetrating single steel and plastic pipes < 15 mm.
more
BSS foam seal<br>S 90

BSS foam seal
S 90

Elastic firestop foam for wall and floor/ceiling penetrations, designed for the protection of single and bunched electrical lines and cables of all types with a cable diameter of up to 32 mm for fire rating S 90 (including optical fibre cables), as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastics. Also permitted for the protection of penetrating single steel and plastic pipes < 15 mm.
more
panel seal<br>S 30 / S 60

panel seal
S 30 / S 60

Panel seal (soft seal) for wall and floor/ceiling penetrations, designed for the protection of both single and bunched electrical lines and cables (including optical fibre cables) – without restrictions imposed on each cable’s overall conductor cross-section – as well as of their supporting structures (cable troughs, trays and ladders) made of steel, aluminium or plastic.
more
Variant N II KS<br>fire protection collar

Variant N II KS
fire protection collar

Fire protection collar, filled with conduits or conduit bundles • Wall penetration: collar mounted on both sides • Foor penetration: one collar bottomside
more
Variant N II A<br>fire protection collar

Variant N II A
fire protection collar

Fire Protection Collar for sealing various types of pipes. • Wall duct: Two Fire Protection Collars • Floor duct: On floor underside a Pipe collar
more
ABA cable coating

ABA cable coating

Ablation coating, i.e. a compound which expands when exposed to heat, suitable for indoor use Flame propagation along the cables is prevented for at least 30 minutes (Test Report No. U 99059 of iBMB BS (Institut für Baustoffe, Massivbau und Brandschutz / German Institute for Building Materials, Concrete Construction and Fire Protection)  
more
BMA cable coating

BMA cable coating

IEC Test EN 60332 | 60332 • Ablative coating (cooling action by heat absorption), suitable for electrical lines • Permitted for indoor and outdoor use (refineries, industrial facilities etc.)   UL-Link
more
BaGe<br>fire protection bandage

BaGe
fire protection bandage

Fire protection bandage made of a difficult-to-ignite (hardly flammable) fabric and an intumescent building material.
more
BSD fire protection socket

BSD fire protection socket

Ready assembled fire protection socket for the sealing of electrical installations. The core inside of the FLAMRO BSD fire protection socket is foaming up in a case of fire and seals the installation opening reliable for at least 90 minutes.
more
BSH fire protection hood

BSH fire protection hood

FLAMRO BSH fire protection hood is manufactured from a unique multi-layer material which in case of fire expands inwards and outwards. This completely seals the ceiling opening with an insulating foam which prevents or considerably delays the spreading of fire. At the same time the foam offers additional insulation of the space or ceiling cavity, prevents extreme heating and the ignition of flammable materials such as dust.
more
EASY duct system

EASY duct system

Der FLAMRO Kabelkanal EASY! Der montagefertige Brandschutzkanal mit Stumpfstoßtechnik für jedermann! Erhebliche Reduzierung der Montagekosten bei minimalem Arbeitsaufwand.
more
FKS duct system

FKS duct system

Customised solutions – made to measure and reliable! Circuit integrity classes E 30 – E 90 Fire resistance classes I 30 – I 120 Examples: Transition areas of two-/three-sided cable ducts Customised routing of duct elements around door and window openings or joists where use of standard bow pieces is not possible due to space constraints.
more
SPN assembly duct

SPN assembly duct

Fire resistance classes I 30 to I 90 and E 30 bo E 60
more
N-B fire protection collar

N-B fire protection collar

FLAMRO N-B pipe penetration seal consists of an intumescent building material and a metal casing.
more